HG-CF-962 Rev. V - 17.09.12
Page 1
B06 & X06
Metallic Models
04 Series
This pump is Atex approved for use
in potentially explosive atmospheres
Group II category 2
SERVICE & OPERATING MANUAL
AIR OPERATED DOUBLE DIAPHRAGM PUMP
Table of Contents
Service / Maintenance Log, Recycling 2
Dimensions 3
Performance Curve 3
Technical Data & Temperature limitations 4
Explanation of Pump Nomenclature 4
Principle of Pump Operation 5
Installation guide 5
Important Warnings & Safety Information 6
Troubleshooting 7
Grounding the Pump 7
Warranty 8
Service 8
Air Valve Overhaul 8
Wet-side Overhaul 8
Exhaust Safety 9
High Temperature Inst. 9
Parts List 10
Assembly Drawing 11
Declaration of Conformity 12
II 2 GD c
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - B06 & X06

HG-CF-962 Rev. V - 17.09.12 Page 1 B06 & X06 Metallic Models 04 Series This pump is Atex approved for use in potentially explosive atmospheres

Page 2 - Service / Maintenance Log

HG-CF-962 Rev. V - 17.09.12 Page 10 PARTS LIST REF. PART No. DESCRIPTION QTY 1 D215 SOCKET HEAD CAP SCREW M6 x 20 16 2 C048 WASHER M6 8 3

Page 3 - HG-CF-962 Rev. V - 17.09.12

HG-CF-962 Rev. V - 17.09.12 Page 11 Exploded General Assembly :- B06 Metallic Pump. Refer to page 10, Parts List table for item Ref. Nos. Lip Seal Pos

Page 4 - Materials

HG-CF-962 Rev. V - 17.09.12 Page 12 Des Monaghan, Production & Technical Manager HG-CF-223 (REV 6) IDEX Pump Technologies (Ireland) Ltd., A Unit o

Page 5 - PRINCIPLE OF PUMP

HG-CF-962 Rev. V - 17.09.12 Page 2 Service / Maintenance Log Date Details Completed Contact Information Contact Phone / Fax No. RECYCLING

Page 6 - IMPORTANT!

HG-CF-962 Rev. V - 17.09.12 Page 3 GA Drawing & Performance Curve General Assembly :- B06 Metallic pump, all dimensions +/- 1mm B06 Metallic Pump

Page 7 - TROUBLE SHOOTING GUIDE

HG-CF-962 Rev. V - 17.09.12 Page 4 TECHNICAL DATA FLUID CONNECTIONS CAPACITY MAX SOLIDS MAX DISCHARGE HEAD DISPLACEMENT/STROKE 1/4” BSP 0 - 18 Li

Page 8 - SERVICE

HG-CF-962 Rev. V - 17.09.12 Page 5 PRINCIPLE OF PUMP OPERATION This ball valve type diaphragm pump is powered by compressed air and is a

Page 9 - REF. NO 22

HG-CF-962 Rev. V - 17.09.12 Page 6 Before pump operation, inspect all gasketed fasteners for looseness caused by gasket creep. Re-torque

Page 10 - Page 10

HG-CF-962 Rev. V - 17.09.12 Page 7 TROUBLE SHOOTING GUIDE NOTE :- Check all solutions before dismantling the pump. PROBLEM CAUSE SOLUTION Pump will

Page 11 - Page 11

HG-CF-962 Rev. V - 17.09.12 Page 8 Read these instructions completely, before installation and start-up. It is the responsibility of the purchas

Page 12 - Date : December 01 2009

HG-CF-962 Rev. V - 17.09.12 Page 9 HIGH TEMPERATURE INSTALLATIONS In situations where the temperature of the fluid to be pumped is likely to exceed 1